Your browser doesn't support javascript.
loading
Mostrar: 20 | 50 | 100
Resultados 1 - 20 de 995
Filtrar
1.
Int Orthop ; 2024 Apr 23.
Artigo em Inglês | MEDLINE | ID: mdl-38652245

RESUMO

PURPOSE: Periprosthetic femoral fractures (PPFs) around the hip are challenging complications in orthopaedic surgery, particularly Vancouver type B2 (VTB2) fractures. The surgical management of these fractures is crucial and depends on various factors. Cementless short taper stem with plate osteosynthesis is an alternative surgical technique. This study aims to compare the outcomes of this surgical technique with revision arthroplasty (RA) with long stem in the treatment of VTB2 PPFs. METHODS: This retrospective study was conducted in a single medical institute from February 2010 to May 2019. Patients who had received either total hip arthroplasty or bipolar hemiarthroplasty and subsequently developed a VTB2 PPF were included; patients who sustained intra-operative fractures or received a cemented stem previously were excluded from the analysis. The patients were divided into two groups: group I received RA with cementless long stem, while group II underwent RA with cementless short taper stem with plate osteosynthesis. Demographic data, radiographic and functional outcomes, and complications were analyzed between the two groups. RESULTS: A total of 85 patients diagnosed with VTB2 PPFs were included in the study. There were no significant differences between the two groups in terms of demographic data, including age, gender, mean follow-up times, estimated blood loss, and operative times. The radiographic results showed that there was no significant difference in the incidence of subsidence and implant stability between the two groups. However, group II tended to have less subsidence and periprosthetic osteolysis. Patients in group II had significantly better functional scores (mean Harris hip score: post-operative: 60.2 in group I and 66.7 in group ii; last follow-up: 77.4 in group 1 and 83.2 in group II (both p < 0.05)). There were no significant differences in the overall complication rate, including infection, dislocation, re-fracture, and revision surgery, between the two groups. CONCLUSIONS: Both surgical techniques, cementless long stem and cementless short taper stem with plate osteosynthesis, are effective in the treatment of Vancouver B2 PPFs, with no significant differences in outcomes or complications. However, patients in cementless short taper stem with plate osteosynthesis had better functional scores at both post-operative and the last follow-up.

2.
Rev Bras Ortop (Sao Paulo) ; 59(2): e278-e283, 2024 Apr.
Artigo em Inglês | MEDLINE | ID: mdl-38606142

RESUMO

Objective To evaluate the stability of osteotomies created in the subtrochanteric and trochanteric regions in a pediatric femur model fixed by flexible intramedullary rods. Method Tomographic sections were obtained from a pediatric femur model with two elastic titanium rods and converted to a three-dimensional model. This model created a mesh with tetrahedral elements according to the finite element method. Three virtual models were obtained, and osteotomies were performed in different regions: mediodiaphyseal, subtrochanteric, and trochanteric. A vertical load of 85N was applied to the top of the femoral head, obtaining the displacements, the maximum and minimum main stress, and the equivalent Von Mises stress on the implant. Results With the applied load, displacements were observed at the osteotomy site of 0.04 mm in the diaphyseal group, 0.5 mm in the subtrochanteric group, and 0.06 mm in the trochanteric group. The maximum stress in the diaphyseal, subtrochanteric, and trochanteric groups was 10.4 Pa, 7.52 Pa, and 26.4 Pa, respectively. That is around 40% higher in the trochanteric group in regards to the diaphyseal (control). The minimum stress of the bone was located in the inner cortical of the femur. The equivalent Von Mises stress on the implants occurred at osteotomy, with a maximum value of 27.6 Pa in the trochanteric group. Conclusion In both trochanteric and subtrochanteric osteotomies, fixation stability was often lower than in the diaphyseal model, suggesting that flexible intramedullary nails are not suitable implants for proximal femoral fixations.

3.
J Clin Med ; 13(5)2024 Mar 05.
Artigo em Inglês | MEDLINE | ID: mdl-38592416

RESUMO

Background: Locked plating for distal femur fractures is widely recommended and used. We systematically reviewed clinical studies assessing the benefits and harms of fracture fixation with locked plates in AO/OTA Type 32 and 33 femur fractures. Methods: A comprehensive literature search of PubMed, Embase, Cinahl, Web of Science, and the Cochrane Database was performed. The studies included randomized and non-randomized clinical trials, observational studies, and case series involving patients with distal femur fractures. Studies of other fracture patterns, studies conducted on children, pathological fractures, cadaveric studies, animal models, and those with non-clinical study designs were excluded. Results: 53 studies with 1788 patients were found to satisfy the inclusion and exclusion criteria. The most common harms were nonunion (14.8%), malunion (13%), fixation failure (5.3%), infection (3.7%), and symptomatic implant (3.1%). Time to full weight-bearing ranged from 5 to 24 weeks, averaging 12.3 weeks. The average duration of follow-up was 18.18 months, ranging from 0.5 to 108 months. Surgical time ranged between 40 and 540 min, with an average of 141 min. The length of stay in days was 12.7, ranging from 1 to 61. The average plate length was ten holes, ranging from 5 to 20 holes. Conclusion: This review aimed to systematically synthesize the available evidence on the risk associated with locked plating osteosynthesis in distal femur fractures. Nonunion is the most common harm and is the primary cause of reoperation. The overall combined risk of a major and critical complication (i.e., requiring reoperation) is approximately 20%.

4.
Cureus ; 16(3): e56374, 2024 Mar.
Artigo em Inglês | MEDLINE | ID: mdl-38633962

RESUMO

Periprosthetic femoral fractures (PPFF) around total hip arthroplasty (THA) are one of the leading causes of hip revision. High mortality rates are observed after revision in case of PPFF around THA. To modify risk factors, early postoperative mobilization is necessary. Permissive weight bearing (PWB) is designed to optimize clinical recovery in aftercare. This study aimed to perform a scoping review to summarize the current available evidence on postoperative weight bearing in late PPFF around THA and the implementation of PWB in aftercare. A systematic search was performed on the Cochrane Library, Web of Science, Ovid MEDLINE, EMBASE, and CINAHL databases on January 26th, 2023. Articles were screened in two stages by two independent reviewers. Studies describing adult patients with a history of primary THA who were surgically treated for late PPFF and mentioning prescribed postoperative weight-bearing protocols with relevant outcome measures were included. Seven studies were included, reporting data on 22 patients (age range 47-97 years, BMI range 19-32 kg/m2, ASA classification range 2-3). No studies used PWB in aftercare. The non-weight-bearing group showed no complications. The restricted weight-bearing group had one death and one implant failure. The full weight-bearing group experienced one deep infection and one plate removal because of impingement. The main finding was that, after an extensive systematic search, no articles could be included focusing on PWB in patients with a late PPFF after THA. Addressing this gap in the literature is essential to advancing the understanding of postoperative weight-bearing protocols and PWB for late PPFF around THA.

5.
J Orthop Traumatol ; 25(1): 23, 2024 Apr 23.
Artigo em Inglês | MEDLINE | ID: mdl-38653863

RESUMO

BACKGROUND: The exact positioning of the cephalomedullary (CM) nail entry point for managing femoral fractures remains debatable, with significant implications for fracture reduction and postoperative complications. This study aimed to explore the variability in the selection of the entry point among trauma surgeons, hypothesizing potential differences and their association with surgeon experience. METHODS: In this prospective multicenter study, 16 participants, ranging from residents to senior specialists, partook in a simulation wherein they determined the optimal entry point for the implantation of a proximal femoral nail antirotation (PFN-A; DePuy Synthes) in various femora. The inter- and intra-observer variability was calculated, along with comprehensive descriptive statistical analysis, to assess the variability in entry point selection and the impact of surgeon experience. RESULTS: In this study, the mean distance from the selected entry points to the calculated mean entry point was 3.98 mm, with a smaller distance observed among surgeons with more than 500 implantations (ANOVA, p = 0.050). Intra-surgeon variability for identical femora averaged at 5.14 mm, showing no significant differences across various levels of surgical experience or training. Notably, 13.6% of selected entry points would not allow a proper intramedullary positioning of the implant, thereby rendering anatomical repositioning unfeasible. Among these impossible entry points, a significant skew towards anterior placement was observed (70.6% of the impossible entry points), with a smaller fraction being overly lateral (27.5%) or medial (13.7%). On a patient level, the impossibility rate varied widely from 0 to 35% among the different femora examined, with a significantly higher rate seen in younger patients (mean age 55.02 versus 60.32; t-test for independent samples, p = 0.04). CONCLUSIONS: Significant variations exist in surgeons' selection of entry points for proximal femoral nailing, underscoring the task's complexity. Experience does not prevent the choice of unfeasible entry points, emphasizing the inadequacy of a universal approach and pointing towards the necessity for a patient-specific strategy for improved outcomes. TRIAL REGISTRATION NUMBER: DRKS00032465.


Assuntos
Pinos Ortopédicos , Fraturas do Fêmur , Fixação Intramedular de Fraturas , Humanos , Fixação Intramedular de Fraturas/métodos , Fixação Intramedular de Fraturas/instrumentação , Estudos Prospectivos , Fraturas do Fêmur/cirurgia , Competência Clínica , Variações Dependentes do Observador , Feminino , Masculino
6.
Cureus ; 16(3): e55702, 2024 Mar.
Artigo em Inglês | MEDLINE | ID: mdl-38586703

RESUMO

Background Hip fracture is a public health problem globally, and it poses one of the biggest challenges in healthcare due to its associated complications. Objectives The aim of this study is to investigate the quality of life in adult patients in Khartoum State, Sudan, after they have undergone treatment using a gamma nail for proximal femoral fractures. Methodology This cross-sectional descriptive hospital-based study was conducted at Ibrahim Malik, Omdurman, and Bahri Teaching Hospitals over six months, from April to October 2022. The data were collected using an interview questionnaire that covered relevant aspects of the study. The data were analyzed using IBM SPSS Statistics for Windows, V. 26.0 (IBM Corp., Armonk, NY). The study was approved by the Sudan Medical Specialization Board, and ethical clearance was obtained. Results The study included 37 patients. More than half of the patients (59.5%, n=22) were women. The mean age of cases was 66.7 years (standard deviation, ±15.6). The mean time from the time of the fracture to the time of surgery was eight days (±15). Twenty-three (62.2%, n=23) (JRB1) of the patients started weight bearing on the second postoperative day. Regarding the health-related quality of life, 21.6% of the patients had a good health-related quality of life, 67.6% had a fair health-related quality of life, and 10.8% had a poor health-related quality of life. None of the patients reported an excellent quality of life. Based on the Oxford Hip Score, 54.1% of the patients had satisfactory joint function, 29.7% had mild to moderate hip joint function, 13.5% had moderate to severe hip joint function disturbance, and one patient (2.7%) had severe hip joint function problems. Conclusion In this study, the vast majority of the patients who underwent gamma nail surgery for hip fracture had quality of life scores in the fair to good range afterward. The results indicate that nailing is associated with good outcomes regarding quality of life and is an acceptable option for femoral fracture surgeries in Sudan.

7.
Acta Biomater ; 178: 320-329, 2024 Apr 01.
Artigo em Inglês | MEDLINE | ID: mdl-38479677

RESUMO

Stress-induced corrosion impairs the mechanical integrity of magnesium (Mg) and its alloys as potential orthopedic implants. Although there has been extensive work reporting the effects of stress on Mg corrosion in vitro, the geometric design principles of the Mg-based orthopedic devices still remain largely unknown. In this work, a numerical simulation model mimicking fractured bone fixation and surgical animal models were applied to investigate the effects of the geometric design of Mg screws on the stress distribution and the stress-induced degradation behavior. Finite element (FE) analysis was used for calculation of stress concentrations around the Mg screws, with different thread type, thread pitch, and thread width. Afterward, the Mg screws of the pre-optimization and post-optimization groups exhibiting the highest and lowest stress concentrations, respectively, were implanted in the fractured distal femora and back subcutaneous tissue of rabbits. Encouragingly, there was a significant difference between the pre-optimization and the post-optimization groups in the degradation rate of the stressed screw parts located around the fracture line. Interestingly, there was no significant difference between the two groups in the degradation rate of the non-stressed screw parts. Consistently, the Mg screw post-optimization exhibited a significantly lower degradation rate than that pre-optimization in the back subcutaneous implantation model, which generated stress in the whole screw body. The alteration in geometric design did not affect the corrosion rate of the Mg screws in an immersion test without load applied. Importantly, an accelerated new bone formation with less fibrous encapsulation around the screws was observed in the Mg group post-optimization relative to the Mg group pre-optimization and the poly (lactic acid) group. Geometry optimization may be a promising strategy to reduce stress-induced corrosion in Mg-based orthopedic devices. STATEMENT OF SIGNIFICANCE: Stress concentrations influence corrosion characteristics of magnesium (Mg)-based implants. The geometric design parameters, including thread type, thread pitch, and thread width of the Mg screws, were optimized through finite element analysis to reduce stress concentrations in a fractured model. The Mg screws with triangular thread type, 2.25 mm pitch, and 0.3 mm thread width, exhibiting the lowest maximum von Mises stress, showed a significant decrease in the volume loss relative to the Mg screws pre-optimization. Compared with the Mg screw pre-optimization and the poly(lactic acid) screw, the Mg screw post-optimization favored new bone formation while inhibiting fibrous encapsulation. Collectively, optimization in the geometric design is a promising approach to reduce stress-induced corrosion in Mg-based implants.


Assuntos
Fraturas do Fêmur , Consolidação da Fratura , Animais , Coelhos , Magnésio/farmacologia , Corrosão , Parafusos Ósseos , Fraturas do Fêmur/cirurgia , Análise de Elementos Finitos , Fenômenos Biomecânicos
8.
Unfallchirurgie (Heidelb) ; 127(4): 283-289, 2024 Apr.
Artigo em Alemão | MEDLINE | ID: mdl-38526813

RESUMO

The S3 guidelines on the prophylaxis, diagnostics and treatment of osteoporosis 2023 were completely revised and updated between 2021 and 2023 in accordance with the Association of the Scientific Medical Societies of Germany (AWMF) regulations. The guideline committee consisted of delegates from the 20 specialist societies of the Umbrella Organization Osteology (Dachverband Osteologie, DVO) as well as delegates from the German Society of General Medicine and Family Medicine (DEGAM), the German Society for Nephrology (DGfN) and the Federal Self-help Association for Osteoporosis (BfO).The guidelines focus on preventive measures, diagnostic procedures and treatment approaches for osteoporosis in men aged 50 years and over and postmenopausal women. The main aim is the optimization of care processes, reduction of fracture incidences and maintenance or improvement of the quality of life and functional capacity of patients affected by fractures. A major update to the guidelines includes the introduction of a new risk calculator that can take more risk factors (n = 33) into account and that can estimate the risk of vertebral body and proximal femoral fractures for a 3-year period (previously 10 years). This results in new thresholds for diagnostics and treatment. The programmed app is currently not yet certified as a medical product and a paper version is therefore currently available for patient care with the planned integration of a web-based version of the risk calculator. From the perspective of trauma surgery, the recommendations and innovations for manifest osteoporosis are of particular clinical importance. The focus of the DVO guidelines update is therefore on the implementation of secondary fracture prevention in trauma surgery, orthopedic and geriatric traumatology in the clinical and practical daily routine.


Assuntos
Osteoporose , Fraturas por Osteoporose , Masculino , Humanos , Feminino , Pessoa de Meia-Idade , Idoso , Osteologia , Qualidade de Vida , Osteoporose/diagnóstico , Fraturas por Osteoporose/diagnóstico , Fatores de Risco
9.
Cureus ; 16(1): e53269, 2024 Jan.
Artigo em Inglês | MEDLINE | ID: mdl-38435949

RESUMO

The increasing prevalence of periprosthetic femoral fractures, specifically in the vicinity of the hip, has emerged as a significant issue in recent times. Consequently, there is a need for a thorough examination to enhance the effectiveness of management and treatment approaches. The findings of this study emphasize a significant disparity in the occurrence and characteristics of these fractures, and the multiple cases have highlighted the efficacy of various treatment strategies, such as open reduction and internal fixation, as well as the utilization of cortical strut allografts. Furthermore, the study has identified potential risk factors that have an impact on the characteristics of fractures, providing valuable insights that could be crucial in the development of preventive strategies. This study provides a thorough examination of periprosthetic femoral fractures, highlighting the importance of a cohesive treatment algorithm to improve the handling of such fractures. Moreover, it promotes the need for a collaborative endeavor in conducting research in this field, cultivating a more profound comprehension that has the potential to drive progress in therapeutic approaches, ultimately enhancing patient results over an extended period of time. It is crucial that forthcoming research endeavors persist in expanding upon these discoveries, striving towards a unified methodology in tackling this substantial clinical obstacle.

10.
Front Surg ; 11: 1293049, 2024.
Artigo em Inglês | MEDLINE | ID: mdl-38425376

RESUMO

Backgrounds: This study aims to evaluate the clinical outcome of intramedullary nail supplemented by buttress plate or cable in the treatment of intertrochanteric fracture with broken lateral wall. Methods: From May 2015 to January 2022, patients with unstable intertrochanteric femoral fractures underwent intramedullary fixations strengthened with buttress plates or cables, which depended on the lateral femur wall fragment type. The clinical and radiographic results were compared between the two groups. The hip function was evaluated according to the Harris Hip Scoring (HHS) system. Results: Forty-one patients who sustained intertrochanteric fracture + broken lateral wall were enrolled. Of these, thirty-four received a minimum of twelve months of follow-ups. No statistically significant differences in baseline and operative data were proved between these groups (p > 0.05). Three patients were observed fat liquefaction after surgery (plate group: 2 cases, cable group: 1 case). All patients could sustain partial/full weight-bearing and no case underwent subsequent operation. The HHS of the last follow-up presented 83.6 ± 4.9 points in the plate group and 83.8 ± 3.7 points in the cable group. Conclusions: Intertrochanteric femoral fracture with broken lateral wall is an unstable injury type, the operative treatments of which have been challenging and controversial over the years. Augmentation of intramedullary nailing system using plate/cable contributes to reconstructing the lateral femur wall.

11.
Front Surg ; 11: 1349434, 2024.
Artigo em Inglês | MEDLINE | ID: mdl-38476756

RESUMO

Introduction: Proximal femoral fractures in aging populations represent a significant concern, with an increasing prevalence among individuals aged ≥100 years. The existing research does not provide robust guidance for clinicians managing older patients aged ≥100 years with proximal femoral fractures. We investigated the safety and efficacy of surgical treatment in patients aged ≥100 years with proximal femoral fractures and evaluated the impact of early surgery on their outcomes. Methods: This retrospective cohort study involved 15 patients aged ≥100 years who underwent surgical treatment of proximal femoral fractures; the control group included 137 patients in their 90s. Data were collected between January 2010 and December 2017. Evaluation items included patient characteristics, surgical details, perioperative complication rates, length of hospital stay, the proportion of patients discharged to the same facility or home, rate of regaining walking ability, and 1-year survival rate. Results: The patients aged ≥100 years and those in their 90s had comparable outcomes. Thus, age alone does not dictate surgical success. Early surgery (≤48 h) was associated with trends toward improved perioperative complications, ambulatory ability, and return to original living environment. Discussion: This study underscores the potential benefits of surgical intervention for proximal femoral fractures in patients aged ≥100 years, indicating the relevance of early surgery (≤48 h). Our findings emphasized the importance of timely intervention and evidence-based decision-making for this demographic. Clinicians, policymakers, and patients could benefit from our insights to enhance fracture management strategies, along with future research endeavors to validate and expand our results in larger multicenter cohorts.

12.
Trauma Surg Acute Care Open ; 9(1): e001241, 2024.
Artigo em Inglês | MEDLINE | ID: mdl-38347891

RESUMO

Introduction: The purpose of this study was to describe the outcomes after operative repair of ballistic femoral neck fractures. To better highlight the devastating nature of these injuries, we compared a cohort of ballistic femoral neck fractures to a cohort of young, closed, blunt-injury femoral neck fractures treated with open reduction and internal fixation (ORIF). Methods: Retrospective chart review identified all patients presenting with ballistic femoral neck fractures treated at three academic trauma centers between January 2016 and December 2021, as well as patients aged ≤50 with closed, blunt-injury femoral neck fractures who received ORIF. The primary outcome was failure of ORIF, which includes the diagnosis of non-union, avascular necrosis, conversion to total hip arthroplasty, and conversion to Girdlestone procedure. Additional outcomes included deep infection, postoperative osteoarthritis, and ambulatory status at last follow-up. Results: Fourteen ballistic femoral neck fractures and 29 closed blunt injury fractures were identified. Of the ballistic fractures, 7 (50%) patients had a minimum of 1-year follow-up or met the failure criteria. Of the closed fractures, 16 (55%) patients had a minimum of 1-year follow-up or met the failure criteria. Median follow-up was 21 months. 58% of patients with ballistic fractures were active tobacco users. Five of 7 (71%) ballistic fractures failed, all of which involved non-union, whereas 8 of 16 (50%) closed fractures failed (p=0.340). No outcomes were significantly different between cohorts. Conclusion: Our results demonstrate that ballistic femoral neck fractures are associated with high rates of non-union. Large-scale multicenter studies are necessary to better determine optimal treatment techniques for these fractures. Level of evidence: Level III. Retrospective cohort study.

13.
Med Glas (Zenica) ; 21(1): 208-213, 2024 Feb 01.
Artigo em Inglês | MEDLINE | ID: mdl-38341752

RESUMO

Aim Significant risk factors for femoral nail cutout are well-documented, primarily in the context of single-screw proximal nails. However, it remains uncertain whether those same risk factors are applicable when considering different implant devices. The aim of this retrospective cohort study was to compare cutout risk factors between single- versus double-screw proximal femoral nails. Methods Patients over the age of 75 with intertrochanteric femur fractures (AO Classification 31-A1 or 31-A2) were included in the multicentre study. A study group was treated with a double-screw nail, while a control group received single-screw device. Demographic data, surgical time (min), fracture pattern, distal locking, reduction quality, comorbidities, tip-apex distance (TAD) and 12-month functional scores was collected. Results Two hundred patients were enrolled, 100 for each group. Nine patients experienced a cutout complication, five in the study and four in the control group. The main differences were in distal locking configurations (p<0.05) and in TAD values (p<0.05). The TAD value was higher in the study than in the control group (30.40±0.89 versus 26.79±1.79). No differences at 12-month follow up were reported according to functional scores. Conclusion This study provides insights into the choice of nail systems for intertrochanteric femur fractures, highlighting the importance of distal locking configurations and TAD values. The double screw nail exhibits quite a tolerance by having a higher average TAD value. These findings may guide clinical decisionmaking in the treatment of this challenging fracture type.

14.
Artigo em Inglês | MEDLINE | ID: mdl-38198798

RESUMO

CONTEXT: Prolonged bisphosphonate (BP) treatment for osteoporosis prevents hip and other fractures but causes atypical femoral fractures (AFF). OBJECTIVE: To establish the relationship between patterns of BP use and the risk of AFF and hip fractures. Other potential risk factors for AFF were also examined. DESIGN: Population-based case-cohort study. SETTING: The Danish National Healthcare system maintains longitudinal records of medication use, healthcare utilization, and x-ray images. PARTICIPANTS: Among all 1.9 million Danish adults ≥50, those with subtrochanteric or femoral shaft fractures between 2010-2015 (n = 4,973) were identified and compared to a random sample (n = 37,021). PREDICTORS: Bisphosphonate use was collected from 1995-2015. MAIN OUTCOME MEASURES: Fracture radiographs (n = 4,769) were reviewed by blinded study radiologists to identify AFFs (n = 181) using established criteria. Traditional hip fractures in the random sample (n = 691) were identified by ICD-10. RESULTS: Compared to <1 year of BP use, 5-7 years of use was associated with a 7-fold increase in AFF [adjusted HR = 7.29 (CI: 3.07,17.30)]; the risk of AFF fell quickly after discontinuation. The 5-year number-needed-to-harm for one AFF was 1,424, while the 5-year number-needed-to-treat to prevent one hip fracture was 56. Glucocorticoid and proton pump inhibitor use were independently associated with increased AFF risk. Thirty-one percent of those with AFF had no BP exposure. CONCLUSIONS: The risk of AFF increases with duration of BP use but the beneficial effects of BP therapy in adults ≥50 dramatically exceed this increased risk. Nearly one-third of those with AFF have no BP exposure.

15.
Int J Surg Case Rep ; 115: 109285, 2024 Feb.
Artigo em Inglês | MEDLINE | ID: mdl-38266366

RESUMO

INTRODUCTION AND IMPORTANCE: Periprosthetic fractures are a growing concern due to the increasing frequency of primary joint replacement surgery, with total hip arthroplasty being the most common. The incidence of periprosthetic fractures after revision surgery ranges from 4 to 11 %, with up to 30 % reported after knee revision surgery. This case report aims to describe the treatment of an 81-year-old woman suffering from neglected periprosthetic femoral fracture post hemiarthroplasty. CASE PRESENTATION: An 81-year-old woman with a history of hemiarthroplasty surgery and hypertension was admitted to the ER with pain in her right thigh. She had a middle shaft femoral fracture and was scheduled for open reduction and internal fixation. Despite being fully conscious and having an average pulse rate and blood pressure, she had cardiomegaly and congestive pulmonum. Unfortunately, this patient did not receive appropriate medical treatment after it occurred for 1 month. After surgery, we evaluated the implant, and the implant stabilized the fracture. After 1-3 months after surgery, the LEFS (The Lower Extremity Functional Scale) score was found that the score increase significantly after surgery. CLINICAL DISCUSSION: The Vancouver classification system manages periprosthetic fractures by assessing location, stability, and bone quality. Type A fractures involve the trochanter, while type B fractures are diaphyseal and can extend distally. ORIF is used for subtype B1 fractures, but newer techniques offer shorter operating times and fewer complications. CONCLUSION: From this study, we can conclude that even though neglected cases procedure with ORIF promises a good outcome based on clinical evaluation.

16.
Injury ; 55(3): 111338, 2024 Mar.
Artigo em Inglês | MEDLINE | ID: mdl-38281349

RESUMO

BACKGROUND: The proximal femoral nail is a commonly used fixation device for extra-capsular neck of femur fractures at our UK NHS Trust. Fracture-related infection (FRI) is a catastrophic complication that can be associated with internal fixation. FRI is often diagnosed late, and causes significant impact on the patient and healthcare system, leading to extended hospital stays, reduced quality of life, high healthcare costs and increased mortality and morbidity. AIM: This study aims to evaluate whether failed proximal femoral nails treated at a major trauma centre in the United Kingdom are undergoing routine intraoperative microbiology sampling, as outlined by the FRI Consensus Group in 2020, and also to establish how often fracture-related infection is present in failed proximal femoral nails. METHOD: Electronic patient record systems were reviewed over a 4-year period between 2018-2022 to identify patients who had a proximal femoral nailing, and those who required revision surgery. From this cohort, we then identified whether sampling had taken place during revision surgery, and the number of samples taken. RESULTS: 1041 proximal femoral nails were performed at our trust during the 4-year period. 60 of these implants failed, with 52 of these undergoing revision surgery at our hospital.  Only 56% cases had intra-operative samples taken for microbiology testing, with an average of 9 samples sent per case. Intra-operative sampling confirmed infection in 25% of cases with samples sent.  Of the cases requiring ≥ 3 operations, 75% of cases had confirmed infection. DISCUSSION: The data shows that more can be done to ensure earlier diagnosis of fracture-related infection in failed proximal femoral nails. We should have a high suspicion of FRI in this cohort of patients. This study highlights the importance of a standardised protocol to ensure routine intra-operative sampling during proximal femoral nail revision surgery.


Assuntos
Fraturas do Fêmur , Fixação Intramedular de Fraturas , Fraturas do Quadril , Humanos , Fixação Intramedular de Fraturas/efeitos adversos , Pinos Ortopédicos , Parafusos Ósseos , Qualidade de Vida , Fraturas do Quadril/cirurgia , Fêmur , Fraturas do Fêmur/cirurgia , Estudos Retrospectivos , Resultado do Tratamento
17.
Injury ; 55(2): 111312, 2024 Feb.
Artigo em Inglês | MEDLINE | ID: mdl-38199157

RESUMO

The mechanisms underlying AFF remain unclear, with hypotheses including bone turnover suppression and morphological variation. Recent studies have suggested a potential genetic susceptibility to AFF. A scoping review was conducted using PubMed to identify studies published since 2016. Twenty-one studies were identified, focusing on histological and genetic analysis of AFF patients and Bisphosphonates users. Biopsies and imaging modalities were used to assess histological and morphometric parameters, while genetic sequencing was performed to identify variants in target genes. Genetic studies identified variants in geranylgeranyl diphosphate synthase 1 (GGPS1) and CYP1A1 genes, which play roles in osteoclast function and drug metabolism, respectively. Functional analysis revealed reduced enzymatic activity in mutant variants of these genes, which could be further inhibited by BP use. Other genes, such as ATRAID, ALPL, and COL1A2, were also associated with AFF. Histomorphometric studies supported the hypothesis of bone turnover suppression in AFF, with alterations in tissue mechanical properties and microarchitecture observed, particularly in cortical bone. The findings suggest a potential genetic susceptibility to AFF, with variants in GGPS1 and CYP1A1 genes affecting osteoblast and osteoclast function. Bone turnover suppression and altered tissue properties contribute to the pathogenesis of AFF.


Assuntos
Conservadores da Densidade Óssea , Fraturas do Fêmur , Humanos , Fraturas do Fêmur/diagnóstico por imagem , Fraturas do Fêmur/genética , Fraturas do Fêmur/patologia , Citocromo P-450 CYP1A1/genética , Difosfonatos , Osso e Ossos/patologia , Predisposição Genética para Doença
18.
Bioessays ; 46(2): e2300117, 2024 02.
Artigo em Inglês | MEDLINE | ID: mdl-38059881

RESUMO

Bisphosphonates are a class of drugs which have shown good efficacy in the treatment of post-menopausal osteoporosis, as well as a good safety profile. However, side-effects such as risk for atypical femoral fractures (AFF) have appeared, leading to a decline in use of the drugs by many patients who would benefit from the treatment. While patient characteristics have contributed to improved understanding of risk factors, the mechanisms involved that explain AFF risk have not appeared. Recently, the possibility that the mechanism(s) involved drug-induced modification of cells of the nutrient canals of the femur and subsequent compromise in the bone matrix has been published. The present Hypothesis article builds on the concept presented earlier and expands into biomechanical considerations. An analogy of the mechanisms involved to a real-life scenario is also presented. While this analogy has limitations, consideration of the biomechanical implications of progressive alterations to defects presented by compromised nutrient canal-bone matrix also presents potential relationships with AFF risk.


Assuntos
Fraturas do Fêmur , Osteoporose , Humanos , Difosfonatos/efeitos adversos , Osteoporose/induzido quimicamente , Osteoporose/tratamento farmacológico , Ósteon , Fraturas do Fêmur/induzido quimicamente , Fraturas do Fêmur/tratamento farmacológico , Fatores de Risco
19.
Comput Biol Med ; 168: 107704, 2024 01.
Artigo em Inglês | MEDLINE | ID: mdl-37980797

RESUMO

Atypical femur fractures (AFF) represent a very rare type of fracture that can be difficult to discriminate radiologically from normal femur fractures (NFF). AFFs are associated with drugs that are administered to prevent osteoporosis-related fragility fractures, which are highly prevalent in the elderly population. Given that these fractures are rare and the radiologic changes are subtle currently only 7% of AFFs are correctly identified, which hinders adequate treatment for most patients with AFF. Deep learning models could be trained to classify automatically a fracture as AFF or NFF, thereby assisting radiologists in detecting these rare fractures. Historically, for this classification task, only imaging data have been used, using convolutional neural networks (CNN) or vision transformers applied to radiographs. However, to mimic situations in which all available data are used to arrive at a diagnosis, we adopted an approach of deep learning that is based on the integration of image data and tabular data (from electronic health records) for 159 patients with AFF and 914 patients with NFF. We hypothesized that the combinatorial data, compiled from all the radiology departments of 72 hospitals in Sweden and the Swedish National Patient Register, would improve classification accuracy, as compared to using only one modality. At the patient level, the area under the ROC curve (AUC) increased from 0.966 to 0.987 when using the integrated set of imaging data and seven pre-selected variables, as compared to only using imaging data. More importantly, the sensitivity increased from 0.796 to 0.903. We found a greater impact of data fusion when only a randomly selected subset of available images was used to make the image and tabular data more balanced for each patient. The AUC then increased from 0.949 to 0.984, and the sensitivity increased from 0.727 to 0.849. These AUC improvements are not large, mainly because of the already excellent performance of the CNN (AUC of 0.966) when only images are used. However, the improvement is clinically highly relevant considering the importance of accuracy in medical diagnostics. We expect an even greater effect when imaging data from a clinical workflow, comprising a more diverse set of diagnostic images, are used.


Assuntos
Aprendizado Profundo , Fraturas do Fêmur , Fraturas por Osteoporose , Humanos , Idoso , Registros Eletrônicos de Saúde , Fraturas do Fêmur/diagnóstico por imagem , Radiografia , Fêmur
20.
Arch Orthop Trauma Surg ; 144(1): 251-257, 2024 Jan.
Artigo em Inglês | MEDLINE | ID: mdl-37878075

RESUMO

INTRODUCTION: The STRYKER ADAPT computer-assisted navigation system provides intraoperative feedback to the surgeon regarding implant placement of the Gamma3 nail. The usability of the ADAPT system has not been evaluated. The aim of the study was to investigate the perceived usability of the ADAPT system. MATERIALS AND METHODS: This was a descriptive study with prospectively collected data. ADAPT was introduced at Aarhus University Hospital in February 2021. Prior to introduction, surgeons at the department attended a general introduction to the system. ADAPT was introduced to the surgical nurses and was on display at the surgical ward at more than one occasion, where personal introduction to the system was possible. After introduction, it was mandatory to use ADAPT when using the Gamma3 nail to treat intertrochanteric femur fractures. After each procedure, primary and an eventual supervisor answered a questionnaire, which encompassed the System Usability Scale (SUS) questionnaire. The SUS is a ten-item questionnaire regarding the perceived usability of a system. SUS scores were translated to adjectives, describing user experience on a 7-point adjective scale (worst imaginable, awful, poor, ok, good, excellent, best imaginable). User acceptability, defined as "not acceptable", "marginal" or "acceptable", was also used to interpret the SUS scores. RESULTS: ADAPT was used in 50 procedures by 29 different surgeons, with varying skill-level. Median SUS-score after first-time use of ADAPT for all 29 surgeons was 43 (range: 5-60), which translated to "poor" or "not acceptable". For surgeons who performed ≥ 3 ADAPT-assisted procedures, there were no statistically significant difference in their first to latest SUS-score (median difference: 4.3, p = 0.5). In free text comments ADAPT was positively described as helpful in placement of K-wire and providing educational opportunities for inexperienced surgeons and negatively as inconsistent, slow, time consuming, and causing excessive fluoroscopy. CONCLUSIONS: Usability and acceptability of ADAPT was rated as "poor" or "not acceptable" by the majority of operating surgeons. ADAPT has not been used at our institution based on these findings. The System Usability Scale may be used in further research exploring usability and acceptability of novel computer-assisted navigation systems for orthopaedic surgery.


Assuntos
Fixação Intramedular de Fraturas , Fraturas do Quadril , Cirurgiões , Cirurgia Assistida por Computador , Humanos , Parafusos Ósseos , Fraturas do Quadril/cirurgia , Cirurgia Assistida por Computador/métodos , Computadores , Fixação Intramedular de Fraturas/métodos
SELEÇÃO DE REFERÊNCIAS
DETALHE DA PESQUISA
...